So, I just rewired the 12vcontrol section with a 30amp 12v relay per the drawing, and was off to the races. When I asked about a 12v control circuit, he simply replied "Nope, Most of the carts I've worked on switch 48v THROUGH the key switch"

Sevcon millipak controller wiring diagram 2009104426 cracked#

That's clearly a toughie with very little documentation.įinally the other key that cracked the codeĪs a last resort, I spoke to a "cartguy" on the "JustAnswer" forum. Hard as I tried just couldn't find that relay.Īnd guys, I totally understand "the sound of crickets" when asking the forum about electrical problems on the BBB. There was 12v under the dash alright.the bunch of yellow wires had an unfused 12v picked off from the battery pack with a ground electrically separate from B. When I saw that the 48v section wire colors matched, I was finally showing some progress.Įven at that point though, the puzzler was that the drawing showed a 12 control relay that switched 48v to the contactors. Yes, this diagram was one of the keys to getting this BBB mess unscrewed.

Sevcon millipak controller wiring diagram 2009104426 code#

Then the controller 4 code settled down to a steady green and both axles drive.Īfter about 20 hours of time, mostly in research, its ready to give back to the owners. Yup, I had to replace the front contactor. So, its intelligent.Īnywho, this BBB came with the upgraded accelerator control and after the rewire, the contactors clicked, well at least one of them. One of the sevcon millipak controllers was showing a 4 flash code.Īpparently it checks the interlocks and inputs, then switches B- to energize the coil and if it doesn't see a current draw out to the motors, it says "hey the contactor is not energizing" and it throws the code. I learned a bunch alright, as i trudged through the repair. Yes, it took a bunch of time, but at least I know where the connections connected. I finally, whew, found a diagram that matched the 48v section of the machine, posted here, then I re-wired the 12v control section to match the schematic. I feel for all the folks that had to tie into the wiring for these "one off" machines. What appears to be a 2008 BB Classic, has been with me here since Nov 5th.Īfter the ratfest under the dash and $300 worth of service time at a local "cart shop" that left the very lightly used buggy completely dead, key switch disconnected and a number of wires pulled out of plug jacks.

Sevcon millipak controller wiring diagram 2009104426 update#

Perform pre-installation inspection as required by ANSI specifi-.LE Aquastat problem - schematron.An update for you. INTRODUCTION This product is an automatic, motorized stack damper that has been boiler, the "WARNING" on the wiring diagram and the “DAN - GER” label on the vent damper carton.

Sevcon millipak controller wiring diagram 2009104426 manual#

Honeywell Aquastat L8148A Installation Instructions Manual

sevcon millipak controller wiring diagram 2009104426

AUTOMATIC VENT DAMPER READ AND SAVE THESE INSTRUCTIONS FOR REFERENCE. Wiring diagram for M connection to S/S using wiring harness with two Molex plugs. AFTER D VENT DAMPER IS PLUGGED TO LE, FUSE Fig.ĥ. Aquastat® Controller, be sure that the actuator opens the damper prior to the CONNECTING WIRING HARNESS. Internal view of LA and accompanying components. 3 and 4 show typical wiring diagrams of Aquastat¤ Controllers used in heating systems. LA Aquastat Controller fits the old immersion well spud, this immersion well does not need to be replaced.Ģ. Geno insisted on using my cam as a note pad. Wiring LE with internal plug directly to vent damper in hydronic intermittent pilot system. Wiring LA in oil-fired, forced hot water, tankless, zoned, pump system. Wiring Aquastat® controller, make sure that the damper.LA,E,J AQUASTATfi RELAYS 5 Š12 Fig.ĥ. Wiring diagram for D connection to LE using wiring harness with two molex plugs.įig. The D Automatic Vent Damper is a 24 Vac, motorized stack damper. The plug on the aquastat end has 5 wires - on the plug end at the damper, 4.

sevcon millipak controller wiring diagram 2009104426

I'm looking for a wiring diagram for the Effikal vent damper now. Wiring Aquastat® controller, make sure that the damper. Wiring diagram for D connection to LE using wiring harness with two molex plugs. Honeywell Aquastat L8148A Installation Instructions Manual: Wiring Diagrams Wiring Diagram for Aquastat Relay Check Out.

sevcon millipak controller wiring diagram 2009104426

k, 1 Page.īasic Wiring Diagram for 24V damper and FAD or CAU. Wiring LE with internal plug directly to vent damper in hydronic intermittent pilot. Honeywell Aquastat LA Manual Online: Wiring Diagrams.







Sevcon millipak controller wiring diagram 2009104426